F3
Leisure Power Supply / Voltage Error

Freezer shows F3; interior light may flicker; control panel may reset intermittently.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable mains voltage, Failing internal power supply on main PCB, Loose mains connection at terminal block, Faulty surge suppressor or filter board

How to Fix / Troubleshooting

Safety: Mains voltage is dangerous. Unplug the freezer before opening any electrical compartments. Only perform live voltage checks if you are trained.

Steps to address F3 (power error):

  • 1. Check mains outlet: Plug another appliance into the same socket to confirm stable power. Avoid using long extension leads or multi-way adaptors.
  • 2. Inspect mains cable: Check the Leisure freezer's power cord for cuts, kinks, or burn marks. Replace if damaged.
  • 3. Access terminal block: Remove the rear lower panel and locate the mains terminal block or filter board. Ensure all screws are tight and there are no signs of overheating.
  • 4. Inspect main PCB power section: Look for bulging capacitors or burnt components in the power supply area of the PCB.
  • 5. Replace filter board or PCB if faulty: If the filter/suppressor board is visibly damaged, replace it with a compatible Leisure mains filter board. If the main PCB power supply is defective, replace the main control PCB.
  • 6. After replacement: Restore power and monitor for stable operation without F3 reappearing.