F5
Leisure
Super-Freeze Function Control Fault
Freezer shows F5; super-freeze (fast freeze) function does not work correctly.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or failed super-freeze button, Faulty super-freeze indicator circuit on display PCB, Main PCB not recognizing super-freeze command, Wiring fault between UI and main PCB
How to Fix / Troubleshooting
Safety: Disconnect power before removing the control panel.
Steps to address F5 (super-freeze fault):
- 1. Check button operation: Press the super-freeze button and feel for a positive click. If it is stuck or unresponsive, the switch may be faulty.
- 2. Access display PCB: Remove the control fascia and inspect the button contacts on the display PCB. Clean any contamination and check for cracked solder joints.
- 3. Test continuity: With a multimeter, test the button contacts while pressing the switch. Replace the display PCB if the switch does not make contact.
- 4. Check harness to main PCB: Ensure the command signal wires are intact and connectors are seated.
- 5. Replace main PCB if UI is good: If the button and display PCB are functioning but the main PCB does not activate super-freeze, replace the main control PCB.