Leisure
Poor Cooling / Loss of Capacity
Freezer runs but does not reach set temperature; food is soft or partially thawed.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty condenser coils reducing heat rejection, Failing compressor with low pumping capacity, Partial refrigerant leak in sealed system, Evaporator fan not circulating air properly
How to Fix / Troubleshooting
Safety: Unplug the freezer before cleaning or accessing rear components.
Steps:
- 1. Check door seal: Ensure the Leisure door gasket seals all around. Replace if torn or warped.
- 2. Clean condenser: Brush and vacuum dust from the rear or bottom condenser coils. Improved airflow can significantly enhance cooling.
- 3. Verify fan operation: Confirm that the internal evaporator fan runs when the door is closed (press the door switch to simulate closure).
- 4. Inspect frost pattern: Remove the inner rear panel and check the evaporator. An even frost pattern is normal; a small frosted patch or no frost suggests a sealed system issue.
- 5. If sealed system issue suspected: Do not attempt to add refrigerant yourself. Contact a certified refrigeration engineer to check for leaks or compressor failure.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Condenser Coil
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements