E7
LG Ambient Temperature Sensor Error

Freezer shows E7; ambient temperature readings may be incorrect, causing improper cooling cycles.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ambient thermistor (often near front grille or control panel), Open or shorted sensor wiring, Loose connector at main PCB

How to Fix / Troubleshooting

Safety: Disconnect power before accessing sensors or control boards.

The ambient sensor helps the control adjust operation based on room temperature.

  • Locate ambient sensor: On many LG units, it is near the front toe grille, behind the control panel, or in the hinge area. Refer to the user or service manual if available.
  • Inspect sensor and wiring: Check for physical damage, rodent-chewed wires, or corrosion. Ensure the sensor is not dangling or touching hot components.
  • Test sensor: Disconnect and measure resistance at room temperature. Compare to LG spec. Replace if open, shorted, or far out of range.
  • Secure placement: When installing a new sensor, mount it in the original location so it measures room air, not internal freezer air.

If the sensor and wiring are good but E7 persists, the main PCB input circuit may be faulty and require professional replacement.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor
Check Price on Amazon