LG
Door Switch Failure or Misalignment
Interior light stays on when the freezer door is closed, causing heat and poor cooling near the top.
Advertisements
Possible Causes
Stuck or broken door switch, Misaligned door not depressing switch, Faulty reed sensor not detecting door closed
How to Fix / Troubleshooting
Safety: Unplug the freezer before working on the door switch or light assembly.
- Check light behavior: Press the door switch manually with the door open. The light should turn off. If not, the switch is likely faulty.
- Inspect switch: Remove the switch from the liner and check for broken tabs or burnt contacts.
- Test continuity: Use a multimeter to test the switch operation. Replace if it does not open/close properly.
- Verify door alignment: Ensure the door fully depresses the switch when closed.
Replacing a faulty door switch typically resolves the light staying on and associated warming.