F16
Liebherr LED Lighting / Door Status Circuit Fault

Freezer shows F16; internal light may flicker or not work; door status may be misdetected.

Advertisements

Possible Causes

Failed LED light module, Shorted LED driver on control board, Wiring damage in door frame

How to Fix / Troubleshooting

Safety first: Unplug the freezer before removing light covers or panels.

Steps:

  • Check light module: Remove the interior light cover (usually clipped in). Inspect the LED board for burn marks or corrosion.
  • Test with door switch: Manually activate the door switch or magnet and see if the light responds.
  • Inspect wiring: Follow the light wiring back towards the control area, checking for pinched or broken wires.

Remedy: Replace the LED light module if visibly damaged or non-functional. If multiple lights fail simultaneously, the LED driver circuit on the main board may be defective and require replacement.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements