Freezer runs continuously but does not reach the set temperature; interior only slightly cool.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Do not attempt sealed system repairs yourself.
Steps:
- Check ambient conditions: Ensure the freezer is not installed in a very hot or unventilated space exceeding Liebherr's climate class rating.
- Condenser and ventilation: Clean the condenser and ensure adequate airflow around the appliance.
- Door gasket check: Close a sheet of paper in the door at various points. If it pulls out easily, the gasket may be leaking cold air.
Remedy: If the compressor runs almost constantly and the unit never reaches target temperature despite good ventilation and seals, a sealed system issue is likely. Contact an authorized Liebherr service center for leak detection and repair.