dF
Logik
Defrost Mode Indication / Stuck in Defrost
Display shows dF or a defrost symbol for an extended period; freezer may warm slightly during this time.
Advertisements
Possible Causes
Normal automatic defrost cycle, Defrost relay stuck on main PCB, Defrost sensor misreading temperature, Software glitch in control board
How to Fix / Troubleshooting
Safety first: No immediate hazard, but avoid leaving the door open during diagnosis.
- Wait for cycle completion: Many Logik freezers display a defrost indicator during automatic defrost. This should clear within 20–40 minutes. Monitor temperature with a thermometer.
- Power reset: If dF remains for several hours, unplug the freezer for 10 minutes, then reconnect. This can clear a control glitch.
- Check for excessive warming: If the interior temperature rises significantly and dF does not clear, there may be a control or sensor fault. Refer to E4 procedures to test the defrost sensor and heater.
Note: If the unit repeatedly gets stuck in defrost, the main control board may need replacement by a technician.
Advertisements
Repair Difficulty
Easy