Logik Door Alignment / Hinge Fault

Freezer door does not close properly or pops open after being shut.

Advertisements

Possible Causes

Loose or bent door hinges, Warped door, Overloaded door shelves, Misaligned cabinet or not level

How to Fix / Troubleshooting

Safety first: Unplug the freezer before adjusting hinges to avoid accidental fan or compressor operation.

  • Level the cabinet: Use a spirit level and adjust the front feet so the freezer leans slightly back. This helps the door close by gravity.
  • Inspect hinges: Check the top and bottom hinges for looseness or bending. Tighten hinge screws and replace any damaged door hinge components.
  • Reduce door load: Remove heavy items from the door shelves that may be pulling the door out of alignment.
  • Check gasket contact: Close the door on a strip of paper at several points. If it pulls out easily, adjust the door position or replace the gasket.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Hinge
Check Price on Amazon

We may earn a commission from links on this page.