Magic Chef
Post-Transport Start Failure
Freezer will not start after being transported or moved; lights may work but compressor is silent.
Advertisements
Possible Causes
Oil migration in compressor from laying unit on its side, Start relay failure triggered by movement, Loose internal wiring connection
How to Fix / Troubleshooting
Safety: Do not attempt to run a freezer immediately after it has been on its side or back.
Steps:
- Let it stand upright: After moving, leave the freezer upright and unplugged for at least 4–24 hours (longer if it was on its side) to allow compressor oil to settle.
- Then plug in and test: After the rest period, plug in and set to a cold setting. Listen for compressor start.
- Check start relay and wiring: If it still does not start, inspect the start relay and wiring as described in compressor-related entries.
Note: Running the compressor too soon after transport can cause damage; always allow adequate settling time.
Advertisements
Repair Difficulty
Very Easy
1/5