Magic Chef Post-Transport Start Failure

Freezer will not start after being transported or moved; lights may work but compressor is silent.

Advertisements

Possible Causes

Oil migration in compressor from laying unit on its side, Start relay failure triggered by movement, Loose internal wiring connection

How to Fix / Troubleshooting

Safety: Do not attempt to run a freezer immediately after it has been on its side or back.

Steps:

  • Let it stand upright: After moving, leave the freezer upright and unplugged for at least 4–24 hours (longer if it was on its side) to allow compressor oil to settle.
  • Then plug in and test: After the rest period, plug in and set to a cold setting. Listen for compressor start.
  • Check start relay and wiring: If it still does not start, inspect the start relay and wiring as described in compressor-related entries.

Note: Running the compressor too soon after transport can cause damage; always allow adequate settling time.

Advertisements

Repair Difficulty

Very Easy 1/5
Advertisements