LO
Maytag
Low Temperature Alarm / Overcooling
Display shows LO or Low Temp; freezer feels extremely cold and some items show freezer burn or cracking containers.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Temperature control set too low, Failed temperature sensor (thermistor) reading too warm, Control board stuck in continuous run, Damaged or shorted wiring harness to thermistor
How to Fix / Troubleshooting
Safety first: Unplug the freezer before accessing any internal components or control boards.
- Check temperature setting: Set the freezer to the recommended setting (typically 0°F / -18°C). Wait 24 hours and recheck with a separate thermometer.
- Inspect air vents: Make sure vents inside the freezer are not blocked by food, which can cause uneven temperatures and overcooling in some areas.
- Reset control: Unplug the freezer for 5 minutes, then plug it back in to reset the electronic control. Monitor temperature for 24 hours.
- Test thermistor (advanced): If comfortable, remove the interior panel to access the freezer thermistor. Disconnect it and measure resistance with a multimeter at known temperatures (e.g., ice water ~32°F). Compare to Maytag specs. Replace if readings are out of range.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Freezer Thermistor
Check Price on Amazon