Maytag Interior Light Failure

Freezer light does not turn on when door is opened, but cooling is normal.

Advertisements

Possible Causes

Burned-out LED module or bulb, Failed door switch, Loose light wiring connector

How to Fix / Troubleshooting

Safety first: Unplug the freezer before replacing bulbs or LED modules.

  • Check bulb/module: On older models, unscrew the bulb and inspect the filament. Replace with the correct wattage appliance bulb. On newer models, replace the LED light module as a unit.
  • Test door switch: Press the door switch manually; if the light flickers or comes on, the switch may be sticking and should be replaced.
  • Inspect wiring: Ensure the light harness connector is fully seated.
Advertisements

Repair Difficulty

Very Easy 1/5

Required Part

LED Light Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements