Maytag
Interior Light Failure
Freezer light does not turn on when door is opened, but cooling is normal.
Advertisements
Possible Causes
Burned-out LED module or bulb, Failed door switch, Loose light wiring connector
How to Fix / Troubleshooting
Safety first: Unplug the freezer before replacing bulbs or LED modules.
- Check bulb/module: On older models, unscrew the bulb and inspect the filament. Replace with the correct wattage appliance bulb. On newer models, replace the LED light module as a unit.
- Test door switch: Press the door switch manually; if the light flickers or comes on, the switch may be sticking and should be replaced.
- Inspect wiring: Ensure the light harness connector is fully seated.
Advertisements
Repair Difficulty
Very Easy
1/5
Required Part
LED Light Module
Check Price on Amazon
We may earn a commission from links on this page.