Possible Causes
Dirty condenser coils, Weak compressor, Low refrigerant charge from leak, Evaporator fan not circulating air properly
How to Fix / Troubleshooting
Safety first: Unplug the freezer before cleaning coils or accessing fans.
- Clean condenser coils: Pull the unit away from the wall. Use a coil brush and vacuum to remove dust from the condenser coils and compressor area.
- Check door gasket: Inspect for gaps, tears, or hardened sections. Replace the door gasket if it does not seal tightly.
- Verify fan operation: Ensure both the evaporator fan (inside) and condenser fan (rear) run when the compressor is on.
- Look at frost pattern: Remove the interior back panel and inspect the evaporator. A full, even frost pattern is normal; a partial frost pattern suggests a sealed system issue requiring a professional.