Maytag Long Run Time / Inefficient Operation

Freezer runs constantly and rarely shuts off; exterior sides may feel warm.

Advertisements

Possible Causes

Door gasket leaking warm air, Dirty condenser coils, Freezer located in hot garage or unconditioned space, Low refrigerant or weak compressor

How to Fix / Troubleshooting

Safety first: Unplug before cleaning coils or adjusting components.

  • Check ambient temperature: Ensure the freezer is in a location within Maytag's recommended temperature range (typically 0–110°F). Extreme heat will cause long run times.
  • Inspect gasket: Close the door on a sheet of paper and pull it out. If it slides easily, the door gasket may need replacement or hinge adjustment.
  • Clean condenser: Thoroughly clean the condenser coils and ensure the condenser fan is running.
  • Monitor temperature: If temperature is normal but run time is long, this may be normal in hot environments. If temperature is still high, a sealed system issue may require a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Gasket
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements