F15
Miele Multiple Sensor Correlation Fault

Freezer displays F15 and may show incorrect or fluctuating temperature readings

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

One or more NTC sensors out of calibration, Wiring harness cross-connection, Control board ADC (analog-to-digital converter) fault, Poor sensor mounting causing false readings

How to Fix / Troubleshooting

Safety first: Disconnect power before testing sensors or accessing wiring.

Steps:

  • 1. Compare readings: Use an accurate thermometer to check actual freezer temperature and compare with display.
  • 2. Test all NTC sensors: Locate cabinet, evaporator, and defrost sensors. Disconnect each and measure resistance at a known temperature. Replace any sensor that is significantly out of expected range.
  • 3. Inspect harness routing: Ensure sensor wires are not pinched or routed near high-voltage lines that could induce noise.
  • 4. Reseat connectors: Clean and reseat all sensor connectors at the main control board.
  • 5. Replace control board: If all sensors test correctly and F15 persists, the main control board's sensor input circuitry may be defective.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cabinet NTC Temperature Sensor
Check Price on Amazon