Possible Causes
Slow refrigerant leak in evaporator or condenser, Weak compressor, Partially blocked capillary tube, Condenser coil heavily clogged with dust
How to Fix / Troubleshooting
Safety first: Disconnect power before cleaning coils or accessing the compressor area.
Steps:
- 1. Clean condenser: Thoroughly vacuum and brush the condenser coil. Poor heat rejection can mimic low refrigerant symptoms.
- 2. Check door sealing: Inspect the door gasket for gaps or damage that could allow warm air in, increasing load.
- 3. Monitor frost pattern: With the inner rear panel removed (if accessible), briefly run the unit and observe the evaporator. A healthy system will frost evenly across most of the coil. Frost only at the inlet or in a small section suggests low charge or restriction.
- 4. Avoid DIY refrigerant work: Do not attempt to top up refrigerant. Miele systems require precise charging and leak repair by a certified technician.