Possible Causes
Unit not level, door hinges loose or sagging, shelves or bins interfering, warped door gasket
How to Fix / Troubleshooting
Safety: Use care when adjusting heavy doors.
- Level cabinet: Adjust leveling legs so the freezer tilts slightly back.
- Inspect hinges: Tighten hinge screws at the top and bottom of the door.
- Check for interference: Ensure shelves, baskets, and tall items are not hitting the door.
- Gasket reshaping: Warm the gasket with a hair dryer on low and gently pull it outward where it is not contacting the cabinet.