Monogram No Power / Electrical Supply Failure

Freezer not running at all; no lights, no display, completely dead.

Advertisements

Possible Causes

Tripped circuit breaker, loose power cord connection, failed outlet, blown internal fuse on control board

How to Fix / Troubleshooting

Safety: Use caution when working with household electrical circuits.

  • Check breaker: Verify the dedicated freezer circuit breaker is not tripped. Reset if necessary.
  • Test outlet: Plug a lamp or small appliance into the outlet to confirm power. If dead, contact an electrician.
  • Inspect power cord: Check for cuts, burns, or loose plug blades. Replace the power cord if damaged.
  • Internal fuse: Some Monogram control boards have an onboard fuse. Access the control compartment and visually inspect for a blown fuse. Replacement typically requires board-level work and may be best left to a technician.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Power Cord
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements