Possible Causes
Faulty display PCB, Loose connection between display and main board, Software glitch, Internal fault in temperature calculation circuit
How to Fix / Troubleshooting
Safety: Unplug the freezer before removing the display panel.
Steps:
- 1. Power reset: Disconnect power for 10 minutes and reconnect. Observe if the displayed temperature stabilizes.
- 2. Inspect display connections: Remove the display fascia and check the ribbon cable and connectors for secure fit and no corrosion.
- 3. Compare with actual temperature: Place a thermometer inside the freezer. If the actual temperature is stable but the display is erratic, the issue is likely with the display or control electronics.
- 4. Replace display PCB: If connections are good, replace the display/user interface board with the correct Neff part.
- 5. If still faulty: The main control module may be sending incorrect data and should be checked by a technician.