Neff
Mechanical Vibration or Loose Components
Freezer makes loud rattling or knocking noises during operation.
Advertisements
Possible Causes
Loose evaporator fan blades or housing, Ice buildup contacting fan, Loose internal panels or shelves, Refrigerant lines vibrating against cabinet
How to Fix / Troubleshooting
Safety: Unplug the freezer before removing internal panels or working near the fan.
Steps:
- 1. Identify noise source: Open the door while the noise is present. If it stops, the evaporator fan is likely involved. If it continues, the compressor or external components may be the source.
- 2. Check fan area: Remove drawers and the rear inner panel. Inspect the fan blades for damage and ensure they are firmly attached to the motor shaft. Remove any ice or debris.
- 3. Tighten panels and shelves: Ensure all internal panels, rails, and shelves are properly seated and not vibrating.
- 4. Inspect tubing: At the rear, check that copper or aluminum refrigerant lines are not touching each other or the cabinet. Gently bend them away and insert foam or rubber spacers if needed.