New World Short Cycling / Control Instability

Freezer cycles on and off very frequently (short cycling), with compressor starting and stopping every few minutes.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty thermostat or temperature sensor, Oversized compressor for cabinet, Poor ventilation causing rapid temperature swings, Main control PCB hysteresis settings faulty

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing controls or sensors.

Steps to address short cycling:

  • 1. Verify temperature setting: Ensure the setpoint is reasonable (around −18°C) and not at extremes.
  • 2. Check sensor placement: Confirm the cabinet NTC sensor or thermostat bulb is not directly in the cold air stream from the evaporator fan.
  • 3. Inspect thermostat: On mechanical models, a faulty thermostat can cause rapid cycling; replace if suspected.
  • 4. Improve airflow: Ensure good ventilation around the freezer and avoid blocking internal air passages with food.
  • 5. PCB replacement: If sensors and thermostat are correct but cycling remains abnormal, the main control PCB may have incorrect hysteresis or a fault and may need replacement.

Note: Short cycling can shorten compressor life; address promptly.

Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermostat
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements