New World
Interior Light Circuit Failure
Freezer interior light not working but cooling is normal.
Advertisements
Possible Causes
Blown LED module or bulb, Faulty door switch, Loose light connector, Failed light driver on main PCB (for LED strips)
How to Fix / Troubleshooting
Safety: Unplug the freezer before replacing bulbs or LED modules.
Steps to restore interior lighting:
- 1. Check door switch: Press the door switch manually; if the light does not come on but the switch also controls the fan, see if the fan responds. Replace the switch if it is intermittent.
- 2. Replace bulb or LED module: Remove the light cover and inspect the lamp or LED module. Replace with a compatible New World part.
- 3. Inspect wiring: Ensure the light connector is firmly seated and wires are not damaged.
- 4. PCB driver: If a new lamp/LED and switch do not restore light, the main control PCB light driver may have failed and the board may need replacement.
Note: Use only the specified wattage and type of lamp to avoid overheating the light housing.