H11
Panasonic Communication Error Between Main PCB and Inverter PCB

H11 error, compressor and fan do not run, display may still be lit

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose communication harness between main PCB and inverter, damaged communication cable, failed inverter PCB, failed main control PCB

How to Fix / Troubleshooting

Safety: Disconnect power before accessing rear panels and boards.

Steps:

  • 1. Access boards: Remove the rear lower panel to access the inverter PCB near the compressor, and the upper or front panel to access the main control PCB.
  • 2. Check harness: Locate the multi-core communication cable between the main PCB and inverter. Ensure both ends are fully seated and the locking tabs are engaged.
  • 3. Inspect cable: Look for crushed, cut, or chewed sections along the cable path. Replace the harness if any conductor appears damaged.
  • 4. Connector cleaning: Unplug and replug the connectors several times to clean oxidation from the pins.
  • 5. Power test: Restore power and see if H11 clears. If not, either the inverter PCB or main PCB is not communicating correctly.
  • 6. Board diagnosis: Without Panasonic diagnostic tools, board-level fault isolation is difficult. If wiring is confirmed good, replacement of the inverter PCB is more common, but both may require testing by a technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Inverter PCB
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements