RCA Door Switch or Light Circuit Failure

RCA freezer interior light stays on even when the door is closed; cabinet may get warm near the light.

Advertisements

Possible Causes

Stuck or broken door switch, Misaligned door not pressing switch, Shorted light socket or control board output

How to Fix / Troubleshooting

Safety first: Unplug the freezer before working on the light or switch. Light bulbs can be hot.

Steps to fix light staying on:

  • 1. Check door switch action: Locate the door switch on the frame. Press it by hand; the light should turn off. If not, the switch or wiring is faulty.
  • 2. Inspect door alignment: Ensure the door is not sagging and that it fully depresses the switch when closed. Adjust hinges if necessary.
  • 3. Test switch: Remove the switch (usually snaps or screws out), disconnect wires, and test continuity. It should change state when pressed. Replace with an RCA-compatible door switch if defective.
  • 4. Check bulb and socket: Inspect the bulb and socket for signs of overheating or melting. Replace damaged parts.
  • 5. Verify operation: After replacement, close the door and confirm the light turns off by looking for light leaks around the gasket or listening for the switch click.

Warning: A light that stays on can overheat the liner and raise freezer temperature; correct this promptly.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon