Sharp
Continuous Running – Control or Air Leak Issue
Freezer runs continuously without shutting off; temperature may be normal or slightly low.
Advertisements
Possible Causes
Leaky door gasket causing warm air infiltration, Misadjusted or faulty thermostat/sensor, Blocked air vents inside freezer, Dirty condenser coils reducing efficiency
How to Fix / Troubleshooting
Safety: Unplug before cleaning coils or adjusting internal components.
Steps:
- Door seal: Inspect and replace damaged gaskets. Ensure door closes squarely and hinges are not sagging.
- Internal airflow: Make sure food items are not blocking air vents or the evaporator cover. Rearrange contents to allow circulation.
- Clean condenser: Vacuum dust from condenser coils and ensure the condenser fan (if present) operates correctly.
- Control check: Verify thermostat or sensor operation as described in previous entries. Replace if they do not cycle the compressor off at the correct temperature.