Siemens
False Alarm / Alarm Circuit Fault
Alarm beeps frequently even though the door is closed and temperature seems normal.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty door switch sending intermittent signals, Defective buzzer or alarm circuit on PCB, Sensor noise causing false high-temperature detection, Loose wiring to alarm components
How to Fix / Troubleshooting
Safety: Unplug the freezer before accessing the control panel or switches.
- 1. Confirm actual temperature: Use a thermometer to ensure the freezer is at the correct temperature; if not, treat as a real high-temp issue.
- 2. Check door switch: Test and replace the door switch if it is intermittent or loose.
- 3. Inspect control panel: Remove the fascia and check the buzzer and its wiring for loose connections or corrosion.
- 4. Reset alarm: Use the alarm reset button (if present) after verifying conditions are normal.
- 5. Replace PCB if needed: Persistent false alarms with all hardware good may require main control board replacement.
Note: Do not disable the alarm permanently; it is an important safety feature.
Advertisements
Repair Difficulty
Medium
3/5
Advertisements