SMEG No Cooling – Compressor Not Running

Freezer not cooling at all; interior remains at room temperature, compressor not running, display may be on.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty main control board, Defective compressor start relay or overload, Open thermal protector on compressor, Failed temperature sensor preventing compressor start

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing the compressor or control board. Do not attempt sealed system repairs yourself.

  • 1. Confirm power supply: Check that the outlet has power by testing with another appliance. Verify that any wall switches controlling the outlet are on.
  • 2. Check control settings: Ensure the freezer is not in demo or showroom mode and that the temperature is set to a freezing value.
  • 3. Listen for compressor: After plugging in, listen at the back for a low humming sound. No sound at all suggests a control or start device issue.
  • 4. Inspect compressor start device: Remove the rear lower panel, locate the compressor, and inspect the start relay/overload for burning or cracking. Replace with the correct SMEG part if damaged.
  • 5. Check wiring and connectors: Ensure all harnesses to the compressor and main PCB are firmly connected.
  • 6. Control board evaluation: If the compressor does not receive power despite correct inputs and start components, the main control board may be faulty and should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Compressor Start Relay / Overload Protector
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements