SMEG Continuous Run – Control or Sensor Fault

Freezer runs continuously without cycling off, even when internal temperature is very low.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty temperature sensor, Stuck compressor relay on PCB, Poor door seal causing constant heat gain, Control board logic error

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing sensors or the control board.

  • 1. Check actual temperature: Use a separate thermometer to verify the internal temperature. If it is much lower than set point, suspect a control issue.
  • 2. Inspect door gasket and closure: Repair any leaks that may cause constant warm air infiltration.
  • 3. Test cabinet NTC sensor: Measure resistance and compare to expected values. Replace if out of range.
  • 4. Evaluate main PCB: If the compressor relay remains energized despite correct sensor input, the main board may need replacement.
  • 5. Power reset: Try unplugging for 10 minutes to clear temporary faults, then monitor behavior.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Freezer NTC Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements