E3
Summit Defrost Sensor or Defrost Circuit Error

Summit freezer control panel displays E3 and temperature control becomes erratic or unresponsive.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective defrost sensor or thermal fuse, Open defrost heater circuit, Wiring harness damage between evaporator area and control board

How to Fix / Troubleshooting

Safety first: Unplug the freezer before accessing the evaporator or control board. Avoid touching bare terminals with metal tools.

Steps to troubleshoot E3:

  • Power reset: Disconnect power for 5–10 minutes, then restore. If E3 returns, proceed with inspection.
  • Access evaporator and defrost components: Remove the interior rear panel to expose the evaporator coil. Locate the defrost heater (usually a metal or glass-encased element at the bottom or woven through the coil) and any thermal fuse or defrost sensor attached to the coil.
  • Visual inspection: Look for burnt spots on the heater, broken wires, or a tripped/burned thermal fuse. Check connectors for discoloration or melting.
  • Test the defrost heater: With the freezer unplugged, disconnect the heater leads and measure resistance. A typical heater will show continuity (tens of ohms). An open circuit indicates a failed heater.
  • Check the defrost sensor/thermal fuse: Measure continuity across the thermal fuse or defrost thermostat (if present). An open reading when the coil is cold usually indicates a failed device.
  • Inspect wiring harness: Follow the harness from the evaporator area toward the control board. Look for pinched, cut, or corroded wires and repair or replace as needed.
  • Replace failed components: Install a Summit-compatible defrost heater and/or defrost sensor/thermal fuse if any are open or visibly damaged. Secure them in the original positions and ensure good contact with the evaporator where required.
  • Reassemble and test: Reinstall the interior panel, restore power, and monitor. The E3 code should clear after the control verifies the defrost circuit. Observe several hours of operation to confirm proper defrosting (no rapid ice buildup on the coil).

When to seek service: If all defrost components test good, the main control board may have a failed defrost relay or sensing circuit and should be replaced by a technician.