E6
Teka User Interface / Display Board Communication Fault

Freezer shows E6 and the display or control panel may be unresponsive or show incorrect readings.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged communication cable between UI and main PCB, Oxidized connectors on display board, Faulty display (UI) PCB, Main control board communication driver failure

How to Fix / Troubleshooting

Safety: Unplug the freezer before removing the control panel or accessing the electronics.

  • Access the control panel: Remove screws or clips holding the front/top display panel. Carefully pull it forward.
  • Inspect ribbon cable or harness: Check for kinks, cuts, or signs of moisture. Reseat both ends of the cable (UI board and main PCB) to ensure good contact.
  • Clean connectors: Use contact cleaner on oxidized pins and allow to dry fully before reconnecting.
  • Check for board damage: Look for burnt components, corrosion, or cracked solder joints on the UI board.
  • Test with replacement UI if available: If wiring is intact, swap in a known-good Teka display board to confirm diagnosis.
  • Replace faulty board: Install a new UI/display PCB or main PCB as indicated by testing. Transfer any plastic supports or seals from the old board.

Test: Reassemble the panel, restore power, and verify that the display responds correctly and that E6 is cleared.