Teka
Door Alignment / Gasket Seal Failure
Freezer door does not close properly or pops open; frost builds up around the door area.
Advertisements
Possible Causes
Warped or damaged door gasket, Misaligned door hinges, Obstruction from shelves or baskets, Cabinet not level causing door to swing
How to Fix / Troubleshooting
Safety: No internal electrical work is needed; unplug only if you will adjust hinges near wiring.
- Check for obstructions: Ensure baskets and food packages are not protruding and preventing full closure.
- Inspect gasket: Look for tears, gaps, or hardened sections. Clean the gasket and mating surface with warm soapy water to improve sealing.
- Warm and reshape gasket: Use a hair dryer on low heat to gently warm deformed areas and press them into shape. Do not overheat.
- Level the cabinet: Adjust the front feet so the freezer leans slightly back; this helps the door close by gravity.
- Adjust hinges: If the door is visibly misaligned, loosen hinge screws slightly, reposition the door, and retighten. Replace worn hinges if there is excessive play.
- Replace gasket if necessary: Remove the inner door trim screws or pull out the old gasket from its channel and fit a new Teka gasket, ensuring it seats evenly all around.
Test: Close the door on a strip of paper at several points; you should feel firm resistance when pulling it out.
Advertisements
Repair Difficulty
Easy
2/5