F2
Toshiba
Door Switch Circuit Fault
Freezer shows F2 and interior light or fan may not operate correctly when door is opened.
Advertisements
Possible Causes
Shorted or open door switch, Broken harness in door frame, Corroded connector at PCB, Main PCB input failure
How to Fix / Troubleshooting
Safety: Disconnect power before working on switches or wiring.
Steps:
- 1. Check door switch function: Press the switch manually and observe if the interior light turns on/off (after restoring power briefly). If not, suspect the switch or wiring.
- 2. Remove switch: Unplug the freezer. Pry out the switch from the liner and inspect the terminals and wires.
- 3. Test continuity: Use a multimeter to check the switch in both pressed and released positions. Replace if it does not change state.
- 4. Inspect harness: Follow the wires from the switch into the cabinet as far as accessible. Look for pinched or broken insulation.
- 5. PCB input: If the switch and wiring are good, the main PCB door input circuit may be faulty and require board replacement.
Advertisements
Repair Difficulty
Easy
2/5