Possible Causes
Condenser coils clogged with dust, Inadequate ventilation clearance, Condenser fan failure (if equipped), High ambient temperature
How to Fix / Troubleshooting
Safety: Unplug the freezer before cleaning coils or accessing the rear compartment.
Steps:
- 1. Check clearances: Ensure there is adequate space around the freezer per Toshiba's installation guide (typically several centimeters on sides and back).
- 2. Clean condenser: If the condenser is exposed at the back or bottom, vacuum and brush off dust and lint.
- 3. Verify condenser fan: For models with a condenser fan, confirm it spins freely and runs when the compressor is on. Replace the fan motor if it is seized or not powered.
- 4. Ambient temperature: If the room is very hot, consider improving ventilation or relocating the freezer.
- 5. Monitor: Some warmth on the side walls is normal, but if surfaces are too hot to touch comfortably after cleaning and improving ventilation, have the system checked by a technician.