Toshiba No Power / Control Circuit Failure

Freezer not cooling at all, interior remains at room temperature, compressor not running and no humming sound.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on main PCB, Faulty power cord, Defective main control PCB, Open thermal cutout on compressor

How to Fix / Troubleshooting

Safety: Always unplug the freezer before opening any covers. Mains voltage is present on the control board and compressor terminals.

Steps:

  • 1. Verify outlet: Plug a lamp or other appliance into the same outlet to confirm power is available.
  • 2. Check power cord: Inspect the Toshiba freezer's power cord for cuts, burns, or kinks. If damaged, replace the entire cord set.
  • 3. Inspect main PCB fuse: Remove the control box cover and look for a small glass or ceramic fuse on the PCB. Test continuity with a multimeter. If blown, investigate for shorts before replacing with the same rating.
  • 4. Check control panel: If the display is dead but the outlet and fuse are good, the main control PCB or display PCB may be faulty and require replacement.
  • 5. Compressor thermal cutout: If the compressor previously overheated, the internal overload may be open. Allow several hours to cool and try again; if it never restarts, further compressor/start device diagnosis is needed.
Advertisements

Repair Difficulty

Medium 3/5