Toshiba
Partial Loss of Refrigerant Charge / Low Capacity Cooling
Freezer runs but does not freeze properly; temperature stays around -5°C to 0°C even after many hours.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Micro leak in evaporator coil, Leak at compressor or service port, Restricted capillary tube, Weak compressor
How to Fix / Troubleshooting
Safety: Sealed system work involves refrigerant and must be performed by a licensed technician. Do not attempt to cut or open refrigerant lines yourself.
Diagnostic steps (visual only):
- 1. Check door seal and loading: Ensure the door gasket seals well and the freezer is not overloaded with warm food, which can mimic low capacity.
- 2. Listen and feel: Confirm the compressor runs steadily and the condenser gets warm.
- 3. Inspect frost pattern: Remove the inner rear panel and observe the evaporator after 20–30 minutes of running. A healthy system shows even frost across most of the coil. Frost only near the inlet or no frost suggests low refrigerant or restriction.
- 4. Call a professional: If the frost pattern is abnormal and basic checks are fine, contact an authorized Toshiba service center for leak detection, evacuation, and recharge or component replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Advertisements