AL
Vissani
General Alarm Condition (Temperature or Door)
Display flashes AL and an alarm sounds; temperature may be too high or too low depending on model.
Advertisements
Possible Causes
Door left open too long, High or low temperature beyond alarm threshold, Faulty door switch, Defective temperature sensor or control board
How to Fix / Troubleshooting
Safety: Check food temperature promptly to avoid spoilage.
Steps:
- Silence alarm: Press the alarm reset or set button according to the user manual to silence the buzzer.
- Check door: Ensure the door is fully closed and the gasket is sealing all around. Look for warped door or items blocking closure.
- Door switch test: Press the door switch by hand; the interior light should turn off. If not, the door switch may be faulty.
- Verify temperature: Use a separate thermometer to confirm actual temperature. If normal, suspect a sensor or control issue.
- Sensor and board: Test the cabinet temperature sensor and replace if out of range. If the sensor is good, the main control board may be misinterpreting readings.
Advertisements
Repair Difficulty
Easy
2/5