H1
Vissani
High Temperature Alarm Condition
Display shows H1 or HI; audible alarm sounds and interior temperature is too warm.
Advertisements
Possible Causes
Door left open or not sealing, Recent large warm food load, Failed compressor or low refrigerant charge, Defective temperature sensor or control board misreading temperature
How to Fix / Troubleshooting
Safety: No immediate electrical hazard, but avoid leaving food in unsafe temperatures.
Steps:
- Check door seal: Ensure the door is fully closing and the gasket is not obstructed by packages or frost. Clean gasket with warm soapy water and dry.
- Allow recovery: If you recently loaded warm food or had a power outage, allow 12–24 hours for the freezer to pull down to set temperature. Keep the door closed as much as possible.
- Verify temperature: Place an appliance thermometer inside and compare to the display. If the display shows H1 but the actual temperature is normal, suspect a sensor or control issue.
- Check for running compressor and fans: Listen for compressor and fan operation. If they are not running, investigate compressor start components, fans, or control board.
- Inspect condenser: Clean dust from the condenser coils and ensure adequate airflow around the unit.
- Sensor check: If the unit cools but still shows H1, test and replace the cabinet temperature sensor or main control board as needed.
Food safety: Discard perishable items that have been above 0°F (-18°C) for extended periods.
Advertisements
Repair Difficulty
Easy
2/5