E9
Whynter Compressor Feedback / Current Sense Error

Freezer shows E9; compressor may run continuously or not at all; temperature is unstable

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty current sensor on control board, Loose compressor wiring, Shorted compressor windings, Defective main control board

How to Fix / Troubleshooting

Safety: Unplug the freezer before accessing the compressor compartment. High voltage and hot surfaces are present.

Steps:

  • Inspect wiring: Remove the rear lower panel and check all wires to the compressor, start relay, and control board. Tighten any loose spade connectors.
  • Check for visible damage: Look for burnt wires, melted insulation, or scorch marks near the compressor terminals and on the control board.
  • Test compressor windings: If equipped and trained, use a multimeter to measure resistance between compressor terminals. Very low or uneven readings may indicate a shorted compressor.
  • Board inspection: The current sensor is often integrated on the main PCB. Inspect for burnt components near the compressor output. If damaged, replace the main control board.
  • Reassemble and test: After correcting wiring issues or replacing parts, restore power and monitor operation. If E9 returns, professional diagnosis of the sealed system is recommended.

Warning: Do not attempt to open the sealed refrigeration system yourself; this requires specialized tools and certification.

Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements