Possible Causes

Faulty door switch contacts, Misaligned door not pressing switch fully, Shorted switch wiring

How to Fix / Troubleshooting

Safety: Unplug the freezer before working on the switch or light.

Steps:

  • Check door alignment: Ensure the door fully depresses the switch plunger when closed. Adjust hinges if needed.
  • Test switch: Remove the switch and test continuity. It should open when the plunger is pressed. Replace if it remains closed.
  • Inspect wiring: Look for shorts or damaged insulation around the switch wires. Repair as needed.

Tip: A light that stays on can significantly warm the upper interior; fix promptly to maintain proper temperature.