Whynter
Door Switch Stuck Closed
Freezer interior light stays on even when the door is closed, causing warming near the light
Advertisements
Possible Causes
Faulty door switch contacts, Misaligned door not pressing switch fully, Shorted switch wiring
How to Fix / Troubleshooting
Safety: Unplug the freezer before working on the switch or light.
Steps:
- Check door alignment: Ensure the door fully depresses the switch plunger when closed. Adjust hinges if needed.
- Test switch: Remove the switch and test continuity. It should open when the plunger is pressed. Replace if it remains closed.
- Inspect wiring: Look for shorts or damaged insulation around the switch wires. Repair as needed.
Tip: A light that stays on can significantly warm the upper interior; fix promptly to maintain proper temperature.
Advertisements
Repair Difficulty
Easy
2/5