Whynter
Long Run Time – Heat Load or Control Issue
Freezer is cold but runs almost constantly; very little off time between cycles
Advertisements
Possible Causes
Door gasket leaking, Thermistor out of calibration, Freezer located in hot environment, Evaporator coil partially iced over
How to Fix / Troubleshooting
Safety: Most checks are external; unplug only if removing panels.
Steps:
- Check ambient temperature: Ensure the Whynter freezer is installed within the recommended room temperature range. Very hot rooms cause long run times.
- Inspect door seal: Close a sheet of paper in the door and pull it out. If it slides easily all around, the gasket may be worn or the door misaligned. Adjust hinges if possible or replace the gasket.
- Look for frost on interior walls: Excess frost indicates warm, moist air infiltration. Defrost the unit fully and correct gasket or door issues.
- Verify temperature setting: If set to the coldest setting, try raising the setpoint slightly and monitor run time.
- Sensor check: A misreading thermistor can cause overcooling. If accessible, inspect and test the cabinet thermistor and replace if out of spec.
Tip: Avoid frequent door openings and overloading the freezer, which can also increase run time.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements