Possible Causes

Disconnected or failed temperature sensor, Broken harness, Control board unable to interpret sensor signal

How to Fix / Troubleshooting

Safety: Unplug the appliance before accessing sensors or the control board.

  • Identify which sensor: Consult the user manual; dashes often indicate the main freezer sensor is not providing a valid reading.
  • Check connections: Inspect the sensor connector at both the sensor end and the main PCB for loose or corroded pins.
  • Test sensor: Measure resistance and compare to Zanussi NTC values. Replace the freezer temperature sensor if out of range.
  • Inspect harness: Look for breaks where the cable passes through the cabinet.
  • Replace control board: If the sensor and wiring are good, the main control PCB may be faulty.