E9
Zanussi
Door Switch / Door Sensor Fault
E9 error; freezer temperature fluctuates; compressor may short-cycle.
Advertisements
Possible Causes
Defective magnetic reed door switch, Misaligned door magnet, Broken door switch wiring, Faulty door input circuit on main PCB
How to Fix / Troubleshooting
Safety: Unplug the appliance before testing or replacing switches.
- Locate the door switch: On many Zanussi freezers, the door switch is a small plunger or magnetic sensor in the cabinet frame near the top or side.
- Check operation: Press the plunger or place a magnet near the sensor (for magnetic types) and listen for the interior light turning on/off when power is connected (if safe). If the light does not respond, suspect the switch.
- Test continuity: Remove the switch and test with a multimeter. It should change from open to closed when actuated.
- Inspect magnet and alignment: Ensure the door magnet (if used) is present and aligned with the sensor location.
- Replace faulty parts: Install a new door switch or magnetic door sensor if defective. Reconnect wiring securely.
- Control board: If the switch tests good but the error persists, the main control PCB door input may be faulty.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Door Switch / Door Sensor
Check Price on Amazon