F2
Zanussi Door Switch Circuit Short or Open

F2 code; interior light may stay on or off incorrectly; door alarm may behave erratically.

Advertisements

Possible Causes

Shorted or open door switch, Damaged door switch wiring, Moisture inside switch housing, Faulty door input on control PCB

How to Fix / Troubleshooting

Safety: Unplug the freezer before removing the door switch.

  • Remove switch: Gently pry out or unscrew the door switch from the cabinet frame.
  • Inspect for moisture or corrosion: If the switch is wet or corroded, dry the area and clean contacts if possible.
  • Test with multimeter: Check continuity while pressing and releasing the switch. It should change state reliably.
  • Check wiring: Ensure the wires are not shorted together or broken behind the liner.
  • Replace switch: If faulty, fit a new Zanussi door switch and refit securely.
  • Control PCB: If the switch and wiring are good, the main control PCB may misread the door state and need replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Door Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements