10 FLASH
Amana Flame Sense Loss During Run

Furnace will not start; LED flashes 10 times repeatedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty flame sensor, Poor burner ground, Low gas pressure, Partially plugged burners

How to Fix / Troubleshooting

Safety: Turn off power and gas before removing burners or flame sensor.

  • Clean flame sensor: Remove the flame sensor and gently polish the rod with fine steel wool. Wipe with a clean dry cloth and reinstall.
  • Check ground connections: Verify the burner assembly and control board ground wires are tight and free of rust. Clean contact points with emery cloth if corroded.
  • Inspect burners: Remove burners if accessible. Clean rust and debris from burner ports with a wire brush. Ensure the crossover ports between burners are clear.
  • Verify gas supply: Confirm other gas appliances operate normally. Low gas pressure requires utility or technician service.

If the furnace still loses flame signal mid-cycle, a technician should measure microamp flame current and adjust or replace components as needed.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements