8 FLASH
Amana Low Voltage (24V) Lockout / Incorrect Polarity

Furnace does not respond to thermostat; LED flashes 8 times repeatedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose R or C connections, Short between thermostat wires, Reversed line polarity affecting control board

How to Fix / Troubleshooting

Safety: Turn off power at the breaker before opening the control compartment. Use a non-contact tester to confirm power is off.

  • Check thermostat wiring at furnace: Remove the blower door to access the control board. Verify R, W, Y, G, and C wires are firmly attached and not shorted together.
  • Inspect cable for damage: Follow the thermostat cable from the furnace entry point. Look for staples through the cable or rodent damage. Repair or replace as needed.
  • Verify transformer output: With power on and doors in place (door switch closed), measure between R and C on the board. You should see about 24 VAC. If low or zero, suspect the transformer or primary power.
  • Check line voltage polarity: Confirm hot and neutral are correctly wired at the furnace junction box. Incorrect polarity can cause nuisance lockouts on some Amana boards.

If you are not comfortable working with electrical wiring, contact a licensed technician.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

24V Transformer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements