Steady ON
Amana Normal Operation Indication / No Call for Heat

Status LED on Amana furnace control board is solid ON with no flashing pattern, but furnace does not operate correctly.

Advertisements

Possible Causes

Thermostat not calling for heat, Broken thermostat wire, Incorrect thermostat settings

How to Fix / Troubleshooting

Safety: Turn off power before handling thermostat wiring.

  • Verify thermostat mode: Ensure thermostat is set to HEAT and temperature is above room temperature.
  • Check thermostat batteries: Replace batteries if display is dim or blank.
  • Bypass thermostat (test only): At the furnace control board, briefly jumper R to W with a small piece of wire. If the furnace starts, the issue is with the thermostat or its wiring.
  • Inspect thermostat cable: Look for damage along the run from furnace to thermostat.

If the furnace does not respond even when R and W are jumpered, the control board or safety circuit may be at fault and should be checked by a technician.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Thermostat
Check Price on Amazon