02
American Standard
Pressure Switch Stuck Closed
Error code 02 displayed and furnace inducer motor does not start, no ignition sequence
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty pressure switch contacts, Shorted pressure switch tubing, Inducer motor relay stuck on integrated furnace control, Incorrect pressure switch for American Standard furnace model
How to Fix / Troubleshooting
Safety: Turn off power to the furnace before touching wiring or tubing.
Error 02 typically indicates the pressure switch is detected as closed before the inducer starts.
- Inspect pressure switch tubing:
- Locate the rubber or silicone tube from the inducer housing to the pressure switch.
- Remove the tube and check for water, debris, or kinks.
- Blow gently through the tube to clear any blockage and reinstall firmly.
- Check the pressure switch:
- With power off, disconnect the wires from the pressure switch terminals.
- Use a multimeter on continuity: the switch should be open with no suction applied.
- If it reads closed, the switch is stuck and should be replaced with the correct OEM American Standard pressure switch (match rating in inches W.C.).
- Inspect inducer housing port:
- Ensure the small port where the tube connects to the inducer is not plugged with rust or debris.
- Clean gently with a small drill bit or paper clip (do not enlarge the hole).
- If the switch and tubing are good but the board still reads closed, the integrated furnace control may have a stuck input circuit and should be evaluated by a technician.