American Standard Ignition Failure / No Flame Detected

Error code 12 and furnace starts but shuts down with inducer and blower running, no flame established

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed hot surface igniter, Gas valve not opening, No gas supply to furnace, Loose wiring to igniter or gas valve on American Standard control board

How to Fix / Troubleshooting

Safety: Turn off power and gas before servicing. Gas ignition failures can be hazardous.

Error 12 indicates the control did not detect flame after opening the gas valve.

  • Check hot surface igniter:
    • Observe through the sight glass during a call for heat; the igniter should glow bright orange.
    • If it does not glow, test for 120VAC at the igniter leads during ignition. If voltage is present but no glow, replace the igniter.
  • Verify gas supply:
    • Ensure the manual gas shutoff is open.
    • If other gas appliances are out, contact the gas utility.
  • Check gas valve operation:
    • Listen for a click from the gas valve when ignition should occur.
    • Have a technician measure gas valve voltage and manifold pressure; do not attempt to adjust gas pressure yourself.
  • If you smell gas or suspect a leak, shut off gas immediately and call a professional.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Hot Surface Igniter
Check Price on Amazon