American Standard Pressure Switch Did Not Open After Cycle

Error code 17 and furnace runs inducer but never proceeds to ignition, pressure switch error persists

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Pressure switch stuck closed from previous cycle, Condensate trapped in pressure tubing, Incorrectly sloped vent causing water accumulation, Faulty pressure switch on American Standard condensing furnace

How to Fix / Troubleshooting

Safety: Turn off power before removing tubing or covers.

Error 17 indicates the pressure switch remained closed when it should have opened.

  • Drain condensate:
    • Check the condensate trap and hoses for blockage.
    • Clean the trap and ensure hoses slope continuously to the drain.
  • Clear tubing:
    • Remove and blow out the pressure switch tubing.
  • Test switch operation:
    • With no suction, the switch should be open. Replace if stuck closed.
  • Correct vent slope and support if water is pooling in the vent.