202
Ariston
Air Pressure Switch / Fan Proving Failure
Error 202 appears, furnace starts fan but then shuts down before ignition.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Blocked flue or air intake, Faulty air pressure switch, Split or disconnected pressure tubing, Condensate in pressure tubing
How to Fix / Troubleshooting
Safety: Turn off power before removing covers. Do not operate the furnace with the flue disconnected.
- Inspect flue and air intake: From outside, check that the concentric flue terminal is not blocked by leaves, snow, or nests. Clear any obstruction. Ensure the flue pipes are correctly assembled and not crushed.
- Check pressure switch tubing: Open the furnace front panel and locate the air pressure switch (round device with two small hoses). Inspect the silicone tubes for cracks, kinks, or disconnections. Refit or replace as needed.
- Clear condensate from tubes: If water is visible in the tubes, remove them and blow through gently to clear. Ensure the condensate trap is not blocked so water does not back up into the fan or tubes.
- Test operation: Restore power and call for heat. If the fan runs but error 202 returns, the pressure switch may not be closing and should be tested and replaced by a technician.